![]() I unplugged the air switch and it had a black/charred spade connector. So I looked at the schematic and thought it might be the air switch. They said it was something in the control box and that they needed to replace the whole box for $1100. Had the septic company come to take a look at it. Turned the buzzer off and the light is still on. I would inspect the wiring or tested, and if the wiring is intact then check the pump control switch and then pursue the pump motor. Typically when a connector chars or Burns it's from an overcurrent which in turn could be caused by a short in the wiring or by a seized pump motor. Now with all of that griping aside, you found at least the symptom of a problem in the burned connector. Well you certainly get my Applause for thinking for yourself and not just throwing money at this problem based on what you suggest was a superficial and careless diagnosis by someone who was themselves perhaps being a bit hasty. I will check the power to the pump and the switch today when I get home, and go from there. Hopefully that is the only remaining issue. The safety screw inside it broke, which means the diaphragm/s have ruptured. ![]() See details about your control at /septic/Norweco-Service-Pro-Specifications.pdfĬompressor rebuild kit worked! $85 and about half an hour to install it. Typically a pump failure or high water condition sets off the alarm. Notification of the alarm condition continues automatically every 48 hours until the alarm condition is corrected. "In the event of an alarm condition from the Singulair system, and up to three separate auxiliary treatment components, the registered service provider is automatically notified. Helene, Your ServicePro 801P septic alarm is a Norweco product. ServicePro 801P septic alarm is a Norweco product. New effluent pump and two new floats but alarm still on If so the outlet may be blocked or you may have a bad check valve. I would start by checking the actual liquid level in the sump pit to see if it is in fact correctly turning on the alarm. Sketch: adapted from Norweco's aerobic septic system manual - the control panel showing alarm light and reset button and other controls the company produces other models of controls and aerobic septic system components.Ĭontact information for Norweco as well as other septic system alarms is given We give information about this pump and include company contact information. Illustration at page top: Alderon's Versa'larm™ I/O that can be used to monitor aerobic septic system effluluent levels & pump operation. These questions & answers about de-coding the meaing of various alarms on aerobic septic systems controls, pumps, equipment were posted originally at AEROBIC SEPTIC ALARM SYSTEMS - be sure to check the advice given there. We also provide an ARTICLE INDEX for this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need. This article series discusses how to fix an aerobic septic system alarm that won't shut off, as well as other problems that occur in aerobic septic systems, also known as aeration septic systems or fine-bubble septic aerators. We have no relationship with advertisers, products, or services discussed at this website.Īerobic septic system alarm troublershooting questions & answers. InspectAPedia tolerates no conflicts of interest.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |